How to Read This Register

In one sentence: this page is the single source of truth for what hardware and logical infrastructure exists behind this portfolio, what state each asset is in, and what evidence backs each claim.

Every asset carries one of four verification statuses. They mean specific things and are never blurred:

  • CONFIRMED: direct evidence exists on this site or in the lab itself: a photograph, a configuration that is applied and running, or output captured from the live system. The server room page is the photographic record for the confirmed rows.
  • PARTIALLY VERIFIED: the asset has been stated by the owner (the person who runs this site) but independent corroborating evidence has not yet been published: no photo, no captured inventory output, no serial-level record. Treat the quantity and model as accurate to the owner's account, pending the evidence items in the verification checklist below.
  • PLANNED: an intended future capability. Designed and scoped, not purchased or deployed. Nothing in a PLANNED row should be read as operational.
  • UNKNOWN: insufficient evidence to record a value at all. The field is left marked rather than filled with a guess.

Two rules follow from the site's documentation philosophy (evidence first, explanation second, presentation third). First, this register never converts an owner statement into a confirmed fact; status changes only when evidence lands. Second, physical assets, virtual machines, containers, and logical services are kept in separate inventories: a Kubernetes node is a VM on a Proxmox host, not a physical server, and counting it as one would double-count the fleet.

Register last reconciled: 2026-10-21. Evidence source for all non-CONFIRMED rows: owner statement, 2026-10-21 (updated the same day with configuration-level testimony for the GPU stack nodes and the estate's build sequence), unless a row says otherwise.

Physical Asset Register

Confirmed rows describe the running lab documented on the Homelab Server Room page. Expansion rows describe the stated next phase of the build. Specifications are recorded only where known; empty fields are marked UNKNOWN rather than estimated.

Confirmed, in daily use

Asset IDAssetQtyRole (actual workload)SoftwareNetworkEvidenceStatus
PHY-HOST-D1..D3Desktop PCs, repurposed consumer towers3Proxmox VE hosts: control-plane VM, worker VMs, Longhorn storage nodesProxmox VE 8.xWired Cat6, VLAN 20 access portsPhotographed; documented across the server room and Kubernetes pagesCONFIRMED
PHY-HOST-L1..L4Laptops, repurposed4Proxmox VE hosts for lightweight worker VMsProxmox VE 8.x5 GHz wireless bridge into VLAN 20Photographed; flapping issue and fix documentedCONFIRMED
PHY-NET-SW1Managed switch1802.1Q segmentation: VLAN 10 (management), 20 (cluster), 30 (services); trunk to router and radioVendor firmwareCore of the lab LANConfiguration described on the Kubernetes pageCONFIRMED
PHY-NET-RTRRouter1NAT, DHCP reservations, inter-VLAN routing, firewall between segmentsVendor firmwareWAN to ISP, trunk to switchDocumented on the Kubernetes pageCONFIRMED
PHY-NET-RADIO5 GHz wireless radio1Bridge-mode backhaul carrying cluster traffic to the laptop hostsVendor firmware, fixed channelSwitch trunk portDocumented, including the fixed-channel tuningCONFIRMED
PHY-OPS-1Ops desk monitoring station1Grafana dashboards, logs, hands-on maintenanceBrowser to Grafana on VLAN 10VLAN 10 managementPhotographedCONFIRMED
PHY-PWR-1UPS unitsUNKNOWNPower protection not yet instrumented or documentedNUT plannedHousehold circuits, mapped by breakerNone yetUNKNOWN

Exact makes and models of the confirmed desktops and laptops, their CPU and RAM configurations, and per-node power draw have not been published yet; capturing lshw and dmidecode output per host is item 1 in the verification checklist below. No wattage figures are claimed anywhere on this site because none have been measured.

Owner-stated expansion inventory (pending independent evidence)

The rows below were stated by the owner on 2026-10-21 as the next phase of the build. Until photographs, inventory captures, or configuration exports are published, they carry PARTIALLY VERIFIED or PLANNED status and must not be read as deployed infrastructure.

Asset IDAssetStated qtyIntended workloadKey specificationsStatus
EXP-RACK-1..3Server racks / stacks for hosting infrastructure3House the 24-unit OptiPlex hosting fleet, the JBOD enclosures, and the network core. A fourth, separate large stack holds the GPU rental nodes, and a small standalone position holds the Raspberry Pi utility serverRack units, rail kits, PDU models: UNKNOWNPARTIALLY VERIFIED (owner-stated)
EXP-SFF-1..24Dell OptiPlex 5060 Small Form Factor desktops, hosting fleet24Owner-stated workloads: the self-hosted media library (movies, series, anime), Chakor AI serving ai.tyfsadik.org, and the general self-hosted service estate, spread across the three hosting stacksPer Dell's specification: 200 W PSU (EPA Bronze or Platinum), 1 half-height PCIe 3.0 x16 slot + 1 half-height x4 slot, 4 DDR4 UDIMM slots (64 GB max), 8th-gen Intel Core, chassis 292 x 290 x 92.6 mm. Per-unit CPU/RAM/disk split across this fleet: UNKNOWNPARTIALLY VERIFIED (owner-stated)
EXP-JBOD-1..4JBOD storage enclosures4Bulk storage behind the media library, backups, and dataset retentionEnclosure model, bay count, drive population, interface (SAS/SATA): UNKNOWNPARTIALLY VERIFIED (owner-stated)
EXP-STORE-AGGAggregate storage capacity across the JBODs~2 PB intendedRaw capacity target before redundancy; see the storage capacity model below before quoting this numberRaw vs usable split: not yet established (depends on unknown drive population)PARTIALLY VERIFIED as an intended target; not a measured figure
EXP-NET-CISCOCisco switching infrastructureUNKNOWNManaged switching for the expanded rack infrastructureExact models, port counts, link speeds, VLAN plan: UNKNOWNUNKNOWN
EXP-PI-NETRaspberry Pi utility serverUNKNOWN (at least 1)Owner-stated roles: Pi-hole DNS filtering, security monitoring, and the domain watchdog that detects domain or DNS failures and drives the recovery runbookBoard model and count: UNKNOWNPARTIALLY VERIFIED (owner-stated role; hardware unidentified)
EXP-GPU-NODE-1..20Dell OptiPlex 5060 SFF, GPU compute stack (separate large stack)20Dedicated GPU rental stack, isolated from the hosting fleet per owner statementOwner-stated per-unit configuration: 8th-gen Intel Core i7-8700 (6 cores / 12 threads, up to 4.60 GHz), 16 GB DDR4-2666 (2 x 8 GB), 2x DisplayPort, Gigabit Ethernet only (no Wi-Fi). Chassis spec per Dell: 200 W PSU, half-height PCIe slotsPARTIALLY VERIFIED (owner-stated as built; power and mechanical integration undocumented, see feasibility analysis)
EXP-GPU-1..20RTX 4090-class GPUs (owner specification says "4090 Ti")20GPU compute for rental workloadsReference card: 450 W TGP, 304 mm full-height 3-slot, 12VHPWR, per NVIDIA. Note: NVIDIA has not released a "4090 Ti" SKU as of this writing; the exact model string is pending nvidia-smi evidencePARTIALLY VERIFIED (owner-stated; model string and integration pending evidence)

Power protection, cooling capacity, and backup hardware for the expansion phase are recorded as UNKNOWN until measured. The 9 kW electrical implication of the GPU cluster is worked through in the feasibility section rather than assumed away.

Logical Infrastructure Inventory

Logical assets ride on the physical rows above. VM counts are documented on the Kubernetes Infrastructure page; they are not physical machines and are not double-counted here.

Logical assetRuns onDepends onDocumented atStatus
Proxmox VE virtualization layerPHY-HOST-D1..D3, PHY-HOST-L1..L4Physical hosts, wired/wireless networkProxmox HomelabCONFIRMED
7-node Kubernetes cluster (kubeadm: control plane + workers, Calico, MetalLB, Longhorn, ingress-nginx, cert-manager)VMs across the Proxmox hostsProxmox layer, VLAN 20, storage networkKubernetes InfrastructureCONFIRMED
Self-hosted services (nine applications including DNS and the AI workspace)Kubernetes cluster and VMsCluster, reverse proxy, certificatesData Sovereignty StackCONFIRMED
Self-hosted DNS (filtering/resolution)Service hostsRouter DHCP configuration, upstream resolversSelf-Hosted DNSCONFIRMED
Chakor AI workspace / TYF-AI platformCluster and service hostsModel providers (local and configured cloud), storageChakor, TYF-AICONFIRMED as deployed software; performance claims carry their own methodology notes on those pages
Monitoring: Prometheus + GrafanaCluster, VLAN 10 accessCluster, persistent storageKubernetes InfrastructureCONFIRMED
Zero-trust remote access layerEdge tunnels to the Proxmox and service planeCloudflare account, identity provider rulesProxmox Zero-Trust Private CloudCONFIRMED
Backup and recovery jobs (snapshots + off-host copies)Proxmox and storage layerStorage capacity, schedulingData Sovereignty StackCONFIRMED for the current lab; expansion-phase backup design is PLANNED
Public domains (tyfsadik.org and project sites)GitHub Pages (this site) + tunneled self-hosted servicesRegistrar, DNS provider, tunnel layerProxmox Zero-TrustCONFIRMED

Master Architecture Diagram

One picture of the whole estate: confirmed layers are drawn with solid lines and filled nodes, and owner-stated assets (the three hosting stacks, the 24-unit OptiPlex fleet, the JBOD storage, the Cisco switching, the Raspberry Pi utility server, the media library, and the separate 20-node GPU rental stack) with dashed lines until independent evidence is published. The diagram distinguishes the physical layer (racks, hosts, network) from the virtualization layer (Proxmox), the orchestration layer (Kubernetes), and the service plane (DNS, AI, monitoring, backups, public domains).

flowchart TB ISP["ISP Uplink"] subgraph Confirmed["CONFIRMED: running lab (photographed, in daily use)"] RTR["Router\nNAT / DHCP / inter-VLAN"] SW["Managed Switch\nVLANs 10 / 20 / 30"] RADIO["5 GHz Bridge"] DSK["3 Desktop Proxmox Hosts"] LAP["4 Laptop Proxmox Hosts"] subgraph K8S["7-VM Kubernetes (kubeadm)"] CP["Control plane"] WK["Workers"] LH["Longhorn storage"] OBS["Prometheus + Grafana"] end SVC["Self-hosted services\nDNS / AI workspace / apps"] ZT["Zero-trust tunnel layer"] DOM["tyfsadik.org + project domains"] end subgraph Stated["OWNER-STATED: pending independent evidence"] RACKS["3 hosting stacks + separate GPU stack"] SFF24["24x OptiPlex 5060 SFF hosting fleet"] JBOD["4x JBOD enclosures\n~2 PB intended raw aggregate"] CISCO["Cisco switching\nmodels UNKNOWN"] PI["Raspberry Pi utility server\nPi-hole + security + domain watchdog"] MEDIA["Media library hosting\nmovies / series / anime"] GPUC["GPU rental stack\n20x OptiPlex 5060 SFF\ni7-8700 / 16 GB + RTX 4090-class each"] end ISP --> RTR RTR --> SW SW --> DSK SW --> RADIO RADIO --> LAP DSK --> K8S LAP --> K8S K8S --> SVC SVC --> ZT ZT --> DOM K8S --> OBS RACKS -.-> SFF24 RACKS -.-> JBOD RACKS -.-> CISCO RACKS -.-> GPUC SFF24 -.->|"expansion Proxmox / service nodes"| K8S SFF24 -.->|"hosts"| MEDIA SFF24 -.->|"hosts Chakor AI (ai.tyfsadik.org)"| SVC JBOD -.->|"bulk storage + backups"| LH JBOD -.->|"media storage"| MEDIA PI -.->|"DNS filtering + telemetry + domain watchdog"| RTR CISCO -.-> SW GPUC -.->|"power + mechanical integration undocumented"| CISCO style ISP fill:#1a1a2e,stroke:#ff4444,color:#e0e0e0 style RTR fill:#1a1a2e,stroke:#ff8800,color:#e0e0e0 style SW fill:#1a1a2e,stroke:#00ff88,color:#e0e0e0 style RADIO fill:#1a1a2e,stroke:#00ff88,color:#e0e0e0 style DSK fill:#1a1a2e,stroke:#00d4ff,color:#e0e0e0 style LAP fill:#1a1a2e,stroke:#00d4ff,color:#e0e0e0 style CP fill:#1a1a2e,stroke:#00d4ff,color:#e0e0e0 style WK fill:#1a1a2e,stroke:#00d4ff,color:#e0e0e0 style LH fill:#1a1a2e,stroke:#aa88ff,color:#e0e0e0 style OBS fill:#1a1a2e,stroke:#ffcc00,color:#e0e0e0 style SVC fill:#1a1a2e,stroke:#00d4ff,color:#e0e0e0 style ZT fill:#1a1a2e,stroke:#ff8800,color:#e0e0e0 style DOM fill:#1a1a2e,stroke:#ff8800,color:#e0e0e0 style RACKS fill:#1a1a2e,stroke:#888888,color:#e0e0e0,stroke-dasharray: 5 5 style SFF24 fill:#1a1a2e,stroke:#888888,color:#e0e0e0,stroke-dasharray: 5 5 style JBOD fill:#1a1a2e,stroke:#888888,color:#e0e0e0,stroke-dasharray: 5 5 style CISCO fill:#1a1a2e,stroke:#888888,color:#e0e0e0,stroke-dasharray: 5 5 style PI fill:#1a1a2e,stroke:#888888,color:#e0e0e0,stroke-dasharray: 5 5 style MEDIA fill:#1a1a2e,stroke:#888888,color:#e0e0e0,stroke-dasharray: 5 5 style GPUC fill:#1a1a2e,stroke:#ff4444,color:#e0e0e0,stroke-dasharray: 5 5

Reading guide: solid arrows are paths that carry traffic today. Dashed arrows are owner-stated relationships awaiting independent evidence. The GPU rental stack links into the estate through the switching layer, but its power and mechanical integration is exactly the open question the feasibility analysis below addresses.

Storage Capacity Model: Raw, Usable, Planned

The stated figure for the expansion phase is approximately 2 PB of intended aggregate capacity across 4 JBOD enclosures. Until the enclosure models, bay counts, and drive populations are evidenced, that number is an intended raw target, nothing more. Three distinctions matter before the number is quoted anywhere:

  • Raw capacity is the sum of the label capacities of every physical drive. It is the largest number and the least useful one for planning.
  • Usable capacity is what remains after redundancy (parity or mirroring), filesystem and metadata overhead, and sensible free-space headroom. Parity schemes commonly cost one to four drives per vdev; filesystem overhead and reservation typically cost a further few percent.
  • Backup copies consume capacity again. A 3-2-1 posture (three copies, two media, one off-site) means protected data needs roughly double the usable capacity of the primary copy somewhere in the estate.

Illustrative arithmetic only (not a measurement, and not this lab's configuration): 2.0 PB raw, minus 20 percent for dual-parity redundancy, minus roughly 3 percent filesystem overhead, yields on the order of 1.5 PB usable for the primary copy, before any backup copy is carved out. The real number will be computed from the actual drive population once the JBOD rows above move from PARTIALLY VERIFIED to CONFIRMED, and this section will be updated with the measured split.

One further rule this site applies everywhere: replication is not backup. A replicated or mirrored copy faithfully reproduces accidental deletion and corruption. Independent, point-in-time recovery points (snapshots plus off-host copies, as documented on the Data Sovereignty Stack page) are what make recovery possible.

GPU Cluster Feasibility: OptiPlex 5060 SFF vs RTX 4090

The owner states the stack is twenty OptiPlex 5060 SFF units (8th-gen Core i7-8700, 16 GB DDR4-2666, 2x DisplayPort, Gigabit Ethernet) each paired with an RTX 4090-class GPU, racked separately and reserved for rental workloads. Before that statement can be taken at face value, the chassis and power numbers have to be confronted, because a 450 W RTX 4090 cannot simply be assumed to fit and operate safely inside an unmodified Small Form Factor office PC. The comparison below uses the manufacturers' own published specifications (sources linked in the references).

ConstraintOptiPlex 5060 SFF (Dell spec)GeForce RTX 4090 (NVIDIA spec)Verdict
System power supply200 W (EPA Bronze or Platinum)450 W TGP for the card alone; NVIDIA recommends a minimum 850 W system PSUIncompatible: the card alone draws more than double the entire PSU budget
Auxiliary GPU powerNo 6/8-pin PCIe or 16-pin leads documented on the 200 W SFF supply16-pin 12VHPWR connector, up to 600 W delivery specIncompatible without a PSU and cabling redesign
Slot and bracket1x PCIe 3.0 x16, half-height (low profile) onlyFull-height card, 3 slots thickIncompatible: bracket and slot height
Physical length / clearanceChassis 292 x 290 x 92.6 mm304 x 137 mm card (Founders Edition)Incompatible: the card is longer than the chassis is deep
Slot power deliveryPCIe slot power capped at 75 W by spec, shared with a 65 W-class CPU on a 200 W budgetDraws up to 450 W through slot + connectorIncompatible
CoolingCompact airflow designed around an office CPU and slot-powered GPU (factory options: GT 730 / RX 550 class)450 W continuous heat loadIncompatible: thermal envelope exceeded by an order of magnitude

Conclusion: the OptiPlex 5060 SFF cannot host an RTX 4090 unmodified. The owner reports the GPU stack is already built, which means one of three things must be true for every node, and the register records it honestly as an open documentation gap:

  • the stock 200 W PSU was replaced or supplemented (for example an external ATX or server PSU feeding the card's 16-pin connector), or
  • the card sits outside the closed SFF chassis on a PCIe riser or open-frame mount, or
  • the installed cards are not actually RTX 4090 reference-class parts.

Two evidence items resolve this completely: a photograph of one open node showing the card mounting and power cabling, and the nvidia-smi --query-gpu=name,power.limit --format=csv output from one node. A further naming note: the owner specification says "4090 Ti", but NVIDIA has not released an RTX 4090 Ti SKU as of this writing, so the cards are recorded as RTX 4090-class until the model string is captured. If the stack is ever rebuilt or expanded, the realistic platform options, in order of increasing effort:

  • Tower workstations: full-size towers with 750 to 1000 W+ PSUs and full-length x16 slots (for example Dell Precision or Lenovo ThinkStation class towers) host one 4090-class card each with stock cooling. Highest per-node cost, lowest engineering risk.
  • Open-frame GPU nodes: rack-mounted open frames with server-grade 1600 W+ PSUs and PCIe risers, the standard pattern for multi-GPU density. Cheap per slot, but demands deliberate cable, vibration, and dust management.
  • SFF-respecting alternative: keep the OptiPlex 5060 SFF fleet for what it is genuinely good at (Proxmox nodes, network services, control-plane duties) and, if GPU-in-SFF is ever required, use low-profile 70 W cards in the RTX A2000 / RTX 4000 SFF Ada class that are engineered for exactly this chassis constraint, accepting their much smaller VRAM and throughput.

Electrical planning is part of the same question. Twenty 4090-class cards imply roughly 9 kW of GPU load alone, and 12 kW or more once CPUs, memory, storage, and cooling overhead are included. A single North American 15 A / 120 V household circuit supplies about 1.8 kW maximum, so a stack of this size needs multiple dedicated circuits, and realistically 240 V feeds, plus heat rejection for a continuous multi-kilowatt load in a residential basement. These are solvable problems, but they are electrical and HVAC projects in their own right, and they are recorded here as open engineering questions rather than glossed over.

Status of the GPU stack: PARTIALLY VERIFIED, owner-stated as built and reserved for rental workloads, with the power/mechanical integration and the exact GPU model string undocumented. No performance, uptime, or revenue claims are made anywhere on this site for it.

Build Process: How the Estate Was Assembled

This narrative reconstructs the build from the owner's account (2026-10-21) combined with the photographed and documented evidence for the confirmed layers. Steps that rest on owner testimony alone say so; nothing here is presented as independently verified unless it is. The confirmed basement lab build is documented separately on the Homelab Server Room page; this section covers the larger estate.

1

Site selection and power mapping

Objective: pick the room and learn its electrical limits before racking anything. The basement provides year-round low ambient temperature and acoustic isolation, which is why both the confirmed lab and the stated estate live there. First action: map which outlets share which breakers, and budget the load per circuit. A Canadian household 15 A / 120 V circuit delivers about 1.8 kW maximum, so the estate's total draw determines how many circuits the racks must span. Verification: no warm plugs or cables under sustained load, checked by hand after the first full-power evening. Gap: per-circuit draw has not been instrumented; inline metering is in the verification checklist.

2

Rack assembly and physical layout

Objective: one known place for every device. Per the owner: three large stacks carry the hosting estate (24 OptiPlex 5060 SFF units, the 4 JBOD enclosures, and the network core), a separate large stack carries the 20 GPU rental nodes, and a small standalone position holds the Raspberry Pi utility server. Layout rule carried over from the confirmed lab: network core sits between compute and storage so cable runs stay short, data and power are dressed separately, and nothing is stacked exhaust-to-intake. Verification: photographs of the confirmed room exist; the expansion stacks are PARTIALLY VERIFIED, pending the same photographic record.

3

Network core

Objective: segment before you scale. The confirmed design uses 802.1Q VLANs (10 management, 20 cluster, 30 services) on a managed switch behind a router doing NAT, DHCP reservations, and inter-VLAN routing. The owner states Cisco switching serves the expanded racks; exact models, port counts, and link speeds are UNKNOWN until show version / show vlan brief output is captured. The discipline that matters at this scale: trunk ports between switches carry all VLANs, access ports pin each host to exactly one, and the GPU rental stack gets its own segment so tenant workloads never share a broadcast domain with the hosting estate or the household.

4

Storage: cabling the JBOD fleet

Objective: roughly 2 PB of intended raw aggregate across 4 JBOD enclosures, presented to the hosting fleet for the media library, backups, and dataset retention. JBOD means the enclosure supplies power and connectivity only; redundancy, if any, is decided in software on the host (the capacity model above explains why the 2 PB figure is raw, not usable). Enclosure models, bay counts, drive populations, and the host interface are UNKNOWN. Verification when evidenced: lsblk against the expected drive count, SMART baselines per drive, and a measured raw-vs-usable split replacing the illustrative arithmetic in the storage model.

5

Provisioning the 24-unit hosting fleet

Objective: turn 24 identical OptiPlex 5060 SFF boxes into a managed fleet instead of 24 snowflakes. The pattern that works at this count: image one unit, automate the rest. Each node gets a hypervisor or base OS install (Proxmox VE 8.x is the estate standard, per the confirmed lab), a fixed DHCP reservation, enrollment into monitoring, and a label matching its rack position. Per-unit CPU, RAM, and disk splits across this fleet are UNKNOWN; the capture commands are in the verification checklist. Common error at this step: letting units drift by hand-editing one box; recovery is to re-image from the fleet standard rather than patch the drift.

6

Media library hosting

Objective: serve the movie, series, and anime library from the JBOD-backed storage to household devices. This is a self-hosted media stack on the hosting fleet: storage presented from the JBODs, a media server application organizing and streaming the library, and access limited to the owner's own network and accounts. The legal boundary is documented in the considerations section below: this site neither hosts nor redistributes media, and the library is a private system. Stack details (media server software, transcoding settings, library structure) are UNKNOWN pending configuration evidence.

7

Chakor AI on ai.tyfsadik.org

Objective: serve the Chakor AI workspace at ai.tyfsadik.org from the estate. The owner states the hosting fleet runs it; the software itself is CONFIRMED and documented on the Chakor and TYF-AI pages, including the request lifecycle and the honest note that configured cloud providers mean not all inference traffic stays local. Public reachability follows the estate's standard pattern: the service stays private on its segment and is published through the zero-trust access layer documented on the Proxmox Zero-Trust page, so no inbound ports are opened on the router.

8

GPU rental stack assembly

Objective: 20 GPU nodes, each an OptiPlex 5060 SFF (i7-8700, 16 GB DDR4-2666, Gigabit Ethernet) paired with an RTX 4090-class card, on their own stack and their own network segment, reserved for rental workloads. The feasibility section above is required reading for this step: the stock 200 W PSU and half-height chassis cannot power or house a 450 W card, so the power and mechanical integration method (external PSU, riser, open frame, or a different card) is the single most important documentation gap in this register. Tenant isolation, acceptable-use enforcement, and per-tenant resource limits are also undocumented and are listed in the considerations section.

9

Raspberry Pi utility server: Pi-hole, security, domain watchdog

Objective: keep the estate's hygiene services on hardware independent of the big stacks, so DNS filtering and monitoring survive a rack outage. Owner-stated roles: Pi-hole DNS filtering for the household and lab, security monitoring, and a domain watchdog. The watchdog's job, as documented for this site, is failure detection and recovery: detect when a domain stops resolving or stops serving (distinguishing DNS problems, origin failures, registrar issues, certificate errors, and provider outages), alert the owner, and drive a documented recovery runbook. It does not, and cannot, reverse a registrar or registry action on its own; what it provides is fast detection and a rehearsed path to restore service. Board model and count: UNKNOWN.

10

Operations: monitoring, backup, and the evidence loop

Objective: keep the estate observable and recoverable as it grows. The confirmed lab's pattern (Prometheus metrics, Grafana dashboards, snapshot plus off-host backup copies, and the replication-is-not-backup rule from the Data Sovereignty Stack) extends to the new hardware as it is evidenced. The closing loop is this register itself: every PARTIALLY VERIFIED row above names the exact evidence that will confirm it, and the checklist below is the runbook for collecting it.

Verification Checklist: Evidence to Collect

These are the concrete evidence items that will move rows from PARTIALLY VERIFIED or UNKNOWN to CONFIRMED. Commands are labeled by the environment they run in. Placeholders in angle brackets are environment-specific values the operator supplies; nothing here publishes serial numbers, MAC addresses, or private IPs, which are recorded privately and summarized publicly.

1

Per-host hardware capture (each Linux/Proxmox host)

Objective: publish make, model, CPU, RAM, and disk population per host. Verify success by matching the captured model string against the physical label on the chassis.

sudo dmidecode -t system | grep -E "Manufacturer|Product Name"
sudo lshw -short -C cpu -C memory -C disk
lsblk -d -o NAME,MODEL,SIZE,ROTA
2

Drive health baseline (each storage host)

Objective: establish SMART baselines before trusting any capacity claim. Common error: running against a USB-attached enclosure that hides SMART; recover by attaching through the HBA or using the enclosure's documented passthrough.

sudo smartctl -a /dev/<disk> | grep -E "Model|Capacity|Power_On_Hours|Reallocated"
3

Network inventory (managed switches)

Objective: record exact switch models, port maps, and VLAN configuration. On Cisco IOS-class gear: show version, show vlan brief, show interfaces status. Export the running configuration to offline storage before any change.

4

Virtualization and cluster inventory (Proxmox shell and control plane)

Objective: reconcile the VM inventory against the physical hosts so nothing is double-counted.

pvesh get /nodes --output-format json
qm list
kubectl get nodes -o wide
5

Photographic record

Objective: photograph each rack, enclosure front and rear (model labels visible), and the patched switch panels, then publish selected frames the way the server room page already does. Recovery rule: if a photo exposes a serial or address, retake or crop rather than publish.

6

Power measurement

Objective: replace every unmeasured wattage on this site with a number from an inline meter, per circuit and per rack, before the GPU cluster's electrical design is finalized.

References

Sources for the specifications quoted above. A vendor specification sheet establishes what a product is; it does not establish that this lab owns one, which is why these citations support the feasibility analysis and not the asset statuses.